RECENT PROJECTS
We strive to give our client the most efficient solutions while employing the latest available technology on the market.
During the design phase we coordinate extensively with the client QA/QC and engineering teams to make sure there is clarity for the Basis of Design.
The relevant applicable ISPE codes for the pharmaceutical facility are strictly adhered to.

- Complete facility HVAC plant room design. Plant room running at <0.6 KW/ ton (verified at site)
- Ampoule Injectable facitlity covering 16,000 SQFT area.
- OSD facility covering 16,000 SQFT area.
- Reference Mr. Mohd Ali Sb CEO

- Nutraceutical facility covering 33,800 SQFT area. Liquid Dehumidification System
- Liquid Sterile lyophilizer, Eyedrop Area HVAC design for ISO class 5 area
- OSD facility covering 27,700 SQFT area. Liquid Dehumidification System
- Energy Simulation for warehouse and OSD area wrt to LEED Standard Renewable Energy System
- Cream & Ointment Area, Face building & Offices Area HVAC Design
- Reference: Mr.Mohd Ali Sb CEO Mr. Saqib 0307-2228847

- Utility systems for sterile area designed including PW system, WIFI system, Clean steam system, Compressed air system, Nitrogen generation system
- Sterile Area covering approximately 14,000 SQFT

- 3D Revit design BIM modeling reduces 15% HVAC contracting cost.
- Efficient Chilled water plant room design with LEED platinum standard. 500 Tr plant room operating @0.46 KW/RT
- References: Mr Bilal CEO 0321-2150007 , Mr. Sadaruddin 0333-03075, Mr. Hamid 0316-3330679

PFIZER WEST WHARF
- Pfizer West Wharf facility complete HVAC plant room design. Plant room running at<0.6 KW/ton (verified at site)
- 2 Warehouses approx 25000 SQFT HVAC & Fire Fighting Hydraulic Design approved by XL Catlin
PFIZER PUFF
PFIZER PUFF (Pfizer upgraded future factory complete OSD facility design (81,070 SQFT area)
Scope of Work
- Complete HVAC Design of the project.
- Mechanical works including PW, plant steam, compressed air, Nitrogen, natural gas, plumbing, drain and process drain systems.
- Fire Fighting works
- Elevators
Basic of design document verified by PFIZER regional quality and engineering team leads.
Design Document Included:
- The ISO class to be maintained within the rooms.
- The air changes per hour to be maintained.
- Type of system proposed.
- General specification of critical equipment such as AHU’s and filters.
- Room pressurization and airflow schemes

• PFIZER PUFF (Pfizer upgraded future factory) complete facility design for HVAC, mechanical/utilities, fire fighting,
transportation systems. Design verified by PFIZER global team.
• Pfizer West Wharf facility complete HVAC plant room design. Plant room running at < 0.6 kW/ton (verified at site)
• 2 Warehouse Fire Fighting Hydraulic Design approved by XL Gap
• Steroidal area HVAC design with CFD analysis and secondary primary units to reduce HVAC energy cost.
• Consolidated fire and smoke simulation approved and acknowledged by Mr. John Pfizer Engineering Head New York
•Refernces:
1. Mr. Zawbar Eng Hd, 0301 8480129
2. Mr. Rafay 0301 8424360

• Efficient Chilled water plant room design with LEED platinum standard. 500Tr plant room operating @0.46 kW/RT
• 3D revit design BIM modeling reduces 15% HVAC contracting Cost.
• Refernces:
1. Mr. Bilal CEO 0321 2150007
2. Mr. Sadaruddin 0333 0307586
3. Mr. Hamid 0316 3330679

• Liquid Dehumidification System. WHO complied units. Lower Initial and running cost, maintains RH upto 18%.
• Energy Simulation for Warehouse and OSD area
wrt to LEED Standard
• Renewable Energy system installation with net zero energy for HVAC system.
• Liquid Sterile HVAC design for ISO class 5 area with EMS area.
•Refernces:
1. Mr. Mohd Ali Sb CEO
chiefexecutive@nabiqasim.com
2. Mr. Saqib 0307 2228847

• Utility systems for sterile area designed including Purified Water systems, Water for injection systems, Clean steam system,
Compressed air system, Nitrogen.
• Reference
1. Mr. Ajmal 0301 8250381